GPTD-PT (General-Purpose Tone Detector Port)
Issue 1 May 2002
8-887
555-233-143
Tone Detector Audit/Update Test (#43)
The GPTD port is refreshed with all time slot information and sanity audit is
performed on the GPTD port.
Table 8-338.
Test #43 Tone Detector Audit/Update Test
Error
Code
Test
Result
Description / Recommendation
ABORT
The system was not able to allocate the resources needed for this test.
1. Wait 1 minute and try again.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Hardware audit failed.
1. Run the short test sequence: test port UUCSSpp short repeat 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. To restore the system performance to normal,
replace the Tone Detector circuit pack containing the defective GPTD port.
PASS
The GPTD port has been successfully refreshed with its translation.