SYNC (Port-Network Synchronization)
Issue 1 May 2002
8-1527
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. This error indicates a problem with the primary DS1 reference. It will be
cleared when the primary reference is restored. The following procedure
should indicate the problem’s source:
1. Enter list configuration board UUCSS to check if the primary DS1
Interface circuit pack is inserted in the carrier.
2. Verify that the administered primary reference matches the DS1
reference from the network synchronization plan.
3. Enter test board UUCSS long to test the primary DS1 Interface
circuit pack.
Check the Error Log for DS1-BD or UDS1-BD errors and see
‘‘DS1-BD (DS1 Interface Circuit Pack)’’
or
Interface Circuit Pack)’’ on page 8-1707
to resolve any errors
associated with the primary DS1 (DS1 or UDS1) interface circuit
pack.
If the only errors against DS1-BD or UDS1-BD are slip errors, then
follow the procedures described in the previous troubleshooting
section. If no errors are listed in the Error Log for the primary DS1
Interface circuit pack, continue with the following steps.
4. Enter test Tone-Clock UUC long to test the active Tone-Clock
circuit pack in the master port network.
Check the Error Log for TDM-CLK errors, and verify that TDM Bus
Clock Circuit Status Inquiry test (#148), passes.
Table 8-593.
Synchronization Maintenance Error Log Entries
Error Type
Aux
Data
Associated
Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test synchronization
1 (a)*
None
WARNING/MINOR (h)
OFF
None
18 (b)
0
disable sync
WARNING
OFF
enable sync
257 (c)*
None
WARNING/MINOR (h)
OFF
None
513 (d)*
None
WARNING/MAJOR (h)
OFF
None
769 (e)
None
MAJOR
OFF
None
1793 (f)
2
2.
It may take up to 1 hour for these alarms to clear via the “leaky bucket” strategy.
0–50
None
MAJOR
OFF
None
2049 (g)
2
0
None
WARNING
OFF
None
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...