M/T-DIG (Maintenance/Test Digital Port)
Issue 1 May 2002
8-1173
555-233-143
50
FAIL
The switch was unable to communicate with the port circuitry used for digital
trunk testing.
100
FAIL
Data was not sent from port 2 to port 3 successfully in asynchronous mode.
101
FAIL
Data was not sent from port 3 to port 2 successfully in asynchronous mode.
102
FAIL
Data was not sent from port 2 to port 3 successfully in synchronous mode.
103
FAIL
Data was not sent from port 3 to port 2 successfully in synchronous mode.
1. Reset the circuit pack via the busyout board UUCSS, reset board
UUCSS, release board UUCSS command sequence.
2. Test the port again via the test port UUCSS02 l command.
3. If the test fails again, replace the circuit pack.
PASS
The Maintenance/Test digital port digital trunk testing capability is operating
correctly.
Table 8-480.
Test #565 Digital Port Sanity Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page