reset board
reset board UUCSS [repeat#]
!
CAUTION:
This command can be service disrupting and may cause extraneous alarms.
Effects of a reset vary depending upon the type of object being reset and
upon whether the component is duplicated. Consult the section in
8, ‘‘Maintenance-Object Repair Procedures’’
on the relevant maintenance
object for details.
When a port circuit pack is specified, the reset board command performs a
software reset of every administered port on the circuit pack. Every port must be
busied out before the port circuit pack is reset.
On critical-reliability systems (duplicated PNC), reset of an Expansion Interface,
Switch Node Interface, Switch Node Clock, or DS1 Converter circuit pack on the
active PNC is not permitted. Standby components must first be busied out before
entering the reset.
Cabinet number and repeat both default to 1. For more information, see the
following sections:
‘‘Common Input Parameters’’ on page 7-6
.