![Avaya S8700 Series Maintenance Manual Download Page 1098](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021098.webp)
Maintenance-Object Repair Procedures
555-233-143
8-376
Issue 1 May 2002
BRI Layer 3 Query Test (#629)
This test is used to check the application layer communications between the
switch and the endpoint or adjunct.
For BRI endpoints, an application message containing the appropriate endpoint
service state is sent by the switch to the endpoint. The endpoint responds with an
acknowledgment to the application message.
For ASAI and Avaya adjuncts, this test is not executed from the administration
terminal. Rather, a query message is automatically sent by the switch every two
minutes. Failure of the switch to receive a response to a query from the adjunct is
logged in the Hardware Error Log.
Table 8-158.
Test #629 BRI Layer 3 Query
Error
Code
Test
Result
Description / Recommendation
1005
ABORT
The endpoint’s MIMs Supported? field is administered to “no.”
1. Use the change station extension command to change the parameter
only if the endpoint documentation reflects support for ISDN-BRI
Management and Maintenance Procedures.
1113
ABORT
The signaling link between the switch and the endpoint or adjunct is down.
1. Use the test port PCSSpp long command to clear any errors that prevent
establishment of the signaling link.
2. Examine the results of Test #626 that are executed with the command. If
this test aborts or fails, follow the repair procedure for the Signaling Link
Status test.
3. Escalate problem if BRI Layer 3 Query test continues to abort.
1139
ABORT
The EPN’s packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute the test port long PCSSpp command,
and review the results of the BRI Port Local LAN Loop Around test (#618)
to verify the repair.
1141
ABORT
The PKT-CTRL is out-of-service.
1. Consult the repair procedure for PKT-CTRL (Packet Control Circuit Pack)
Maintenance documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...