![Avaya S8700 Series Maintenance Manual Download Page 866](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102866.webp)
Maintenance-Object Repair Procedures
555-233-143
8-144
Issue 1 May 2002
ASAI-BD (Multi-Application Platform
Board)
Maintenance testing of the common circuit pack is handled by on-board firmware
and server-controlled tests. Maintenance software queries the firmware for error
and alarm information, status, and test results. Firmware automatically reports
error conditions that result in server-controlled testing.
For MAPD board insertion, the switch makes an additional board query if any of
the following circuit packs are inserted:
For any of the previous initial board uplinks, the switch queries the board for
administration data as well as reporting the switch software release and the
system type.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
1
1.
Where UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC); C is the
carrier designation (A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit
pack resides (01 to 21); and pp is the 2-digit port number (01, 02, 03, ...).
Full Name of MO
ASAI-BD
MINOR
test board UUCSS pp
ASAI-BD
ASAI-BD
WARNING
test board UUCSS pp
ASAI-BD
Circuit Pack
Vintage
TN754
49
TN556
49,
80 or greater
TN800
any
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...