![Avaya S8700 Series Maintenance Manual Download Page 1903](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021903.webp)
NO-LIC (No License)
Issue 1 May 2002
8-1181
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1
This error indicates a serial-number mismatch of the
reference IPSI and a subsequent License Error failure. This error is
caused by the:
■
Reference IPSI not responding
■
Expiration of its 6-day timer
Call-processing software stops every new call, except outgoing calls to an
emergency number and incoming calls to an administration number.
b. Error Type 513
This error indicates that the license has expired and
also that:
■
A License Error failure has occurred
■
The 6-day timer has expired
Call-processing software stops every new call, except outgoing calls to an
emergency number and incoming calls to an administration number.
c. Error Type 769
This error indicates that the system is in the Feature
Usage Exceeds Limits mode, and also that a License Error failure has
occurred. The feature usage has exceeded limits, and the 6-day timer has
expired. Call-processing software stops every new call, except outgoing
calls to an emergency number and incoming calls to an administration
number.
d. Error Type 1281
This error indicates that a new license was not
installed after an upgrade. The 6-day timer has expired, and a License
Error failure has occurred. Call-processing software stops every new call,
except outgoing calls to an emergency number or incoming calls to an
administration number.
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
1 (a)
MAJOR
OFF
See Footnote
1
1.
These error types can be cleared by providing the correct License File per local instructions.
513 (b)
None
MAJOR
OFF
See Footnote
1
769 (c)
None
MAJOR
OFF
See Footnote
1
1281 (d)
None
MAJOR
OFF
See Footnote
1
1537 (e)
None
MAJOR
OFF
See Footnote
1
1793 (f)
None
MAJOR
OFF
See Footnote
1
2305 (g)
None
MAJOR
OFF
See Footnote
1
2561 (h)
None
MAJOR
OFF
See Footnote
1
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...