LoRa Data RF Kit

DATA PROTOCOL SELECTION
With the Antenna plugged in and powered up: 

1  Leave Ignition in OFF position
2  Press programming button (antenna button) 8x within 10 seconds (White LED will flash 2x)
3  Choose your protocol below by pressing the programming button:
 

TYPE 1 - Press 2x - Solace RF (Default)

 

TYPE 2 - Press 4x - iDatalink RF

 

TYPE 3 - Press 6x - Fortin RF

 

TYPE 4 - Press 8x - D2D

 

TYPE 5 - Press 10x - Future Use

4  After 3 seconds White LED will flash the number of times according to your selection.

DAC-ADPT

REMOTES

ANTENNA

REMOTE

PROGRAMMING

REMOTES MAY BE

DIFFERENT THAN

PICTURED

REMOTE PROGRAMMING - ONLY REQUIRED FOR D2D

Follow the “Remote Programming Procedure” from the manufactures programming instructions.
Visit the appropriate website or download the “LoRa Antenna Full Guide w/modules” at 

www.solaceremotestarters.com

For Devices that do not have a remote coding procedure follow the procedure below.

ANTENNA IN

RF CONN 2

RF CONN 3

BLACK - GROUND
RED - 12V+ (FUSED)

RF CONN 1

STEP 

1

STEP 

2

STEP 

3

STEP 

4

STEP 

5

Turn the

Ignition ON then

OFF 2x leaving it in 

the ON position at

the 2nd time.

Press and release the 

programming button on 

the antenna 2 times.  

The LED will flash 1x then

2x.

Turn the 

Ignition OFF 

to exit

programming.

Press and hold for 3 seconds

until LED flashes turns on solid.

Release programming

button.

Press the button on each 

transmitter. LED on

antenna will flash 1x

for each remote 

programmed.

2X

HOLD

x1