background image

PROCESSOR

Green

. Steady heartbeat indicates processor is 

running; off indicates no power.

RJ45 LEDs

The RJ45 Ethernet jack has two green LEDs. 

One will glow steady when the link is up and 

the other will flash with activity.

DMX INPUT

Amber

. Steady glow indicates port is receiving 

active  DMX.  Off  indicates  no  incoming  DMX 

signal.

DMX OUTPUT

Green

. Steady glow indicates port is transmit

-

ting DMX. Off indicates no DMX output..

IDENTIFY

Blue.

 Blinks when identify is active.

SD CARD OK

Green

. Steady glow indicates microSD card is 

present.  Off  indicates  no  SD  card  present  or 

SD card error/cannot be read.

Model 6824 4-Port Gateway

Manual

11/06/20

The Pathport® 6824 four-port gateway provides the full  

functionality of other Pathport gateways in a compact, DIN-

rail mountable form factor.
System integrators can now easily put fully customized 

universes of DMX where they are needed. Ideal for use in 

NEMA enclosures. Fully compatible with eDIN interfaces.

The Pathport 6824 features terminal strips that can be removed 

from the card to facilitate easy wiring installation or replacement. 

Make the following connections, 

WITH THE POWER TURNED 

OFF.

POWER

The 6824 is designed to run on either Power-over-Ethernet (PoE), 

or on an auxiliary power supply providing between 24 and 48 volts 

DC. The gateway is Class 2 PoE and will draw up to 8 Watts.
If an auxiliary supply is used, observe the correct polarity when 

wiring  the  power  IN  terminal  plug.  The  earth  ground  terminal 

must be connected to the enclosure’s chassis or electrical ground 

terminal to ensure EMC compliance.

DMX512

DMX connections consist of a shield and data pair. Connect DATA+ 

and DATA- to D1+ and D1-. Observe the same polarity convention 

throughout the system. Connect the cable shield or common to the 

SHLD COM terminal.

NETWORK

All network wiring should follow standard Ethernet rules and be 

installed by a qualified person. As part of the installation, all wiring 

should be certified under the TIA/EIA-568 standard.

CONTACT CLOSURE INTERFACE (CCI)

There  is  a  3-pole  terminal  connector  included  for  dry  contact 

closure input. The CCI supports two functions: 

DMX Hold

 and 

RDM 

Pause

. See the Pathscape Manual for details on how to enable 

these functions

OVERVIEW

CONNECTIONS

STATUS INDICATORS

COM

CC1

NC

NC

D1+

COM

SHLD

D1-

NC

NC

D1+

COM

SHLD

D1-

NC

NC

D1+

COM

SHLD

D1-

NC

NC

D1+

COM

SHLD

D1-

–       +

24–48VDC

7W Max

SD CARD OK

PROCESSOR

IDENTIFY

Port D

Port C

Port B

Port A

INPUT

OUTPUT

INPUT

OUTPUT

INPUT

OUTPUT

INPUT

OUTPUT

FACTORY

DEFAULT

DMX512 Inputs/Outputs (4)

Female RJ45

Ethernet connector

microSD

Card Slot

Connect earth ground to 

protect DMX ports from 

RF interference carried 

on cable shield.

24-48 VDC

Power Input
Use eDIN 1001 power 

supply or equal.

Factory Default/

Reset Button

Fastening Mechanism designed 

for 35 x 7.5mm DIN Rail

Contact Closure/

Expansion Input

Reviews: