background image

Manual# 1140131 

 

 

Quick Installation Guide

  
 

Gateway  

NMEA2000/J1939

 

 

 
 

Summary of Contents for NMEA2000/J1939

Page 1: ...Manual 1140131 Quick Installation Guide Gateway NMEA2000 J1939 ...

Page 2: ......

Page 3: ...Quick Installation Guide for Gateway NMEA2000 J1939 Printed May 2016 Revision Revised www auto maskin com ...

Page 4: ...013 2016 by Auto Maskin AS All rights reserved No part of this document may be reproduced or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Auto Maskin AS ...

Page 5: ...CTION 2 FIRMWARE REVISIONS 2 PRODUCT FEATURES 2 INSTALLATION OF THE GATEWAY 3 UNPACKING THE BOX 3 MOUNTING THE UNIT 3 CONNECTING THE NMEA2000 CABLE 3 CONNECTING THE J1939 CANBUS CABLE 3 J1939 CANbus connections 4 CONFIGURATION 5 NMEA INSTANCE 5 GPS INSTANCE 5 FRONT PANEL INDICATORS 6 BLUE LED 6 GREEN LED 6 MAINTENANCE 7 ...

Page 6: ......

Page 7: ...be carried out by electricians authorized to work with such installations Responsibilities It is the sole responsibility of the installer to ensure that the installation work is carried out in a satisfactorily manner that it is operationally in good order that the approved material and accessories are used and that the installation meet all applicable rules and regulations Note Auto Maskin continu...

Page 8: ...to achieve the best results Firmware Revisions The information in this manual corresponds to the gateways firmware revision 1 0 0 Note The Auto Maskin Marine Pro engine panels require firmware 2 11 and above to support this gateway Product Features Connection to J1939 CANbus network using a 3 pole Wago cage clamp connector Green LED confirming valid J1939 CANbus message transmission NMEA2000 micro...

Page 9: ...locations are shown on the following drawing Connecting the NMEA2000 cable The unit shall be connected to the NMEA2000 network by the 5 way micro C socket on the front Carefully attach the network drop cable to this plug and hand tighten until it is fully seated Take care to match the orientation of the pip inside the socket to the recess inside the drop cable plug The other end of the drop cable ...

Page 10: ...nnection Then simply insert the wire into its connection slot and release the cage clamp by removing the small screwdriver This will produce a secure gas tight connection on wire sizes ranging from 0 08 1 5 mm2 J1939 CANbus connections The terminal connections are numbered as follows Terminal Signal 1 CAN H 2 Ground 3 CAN L These are labeled on the unit case ...

Page 11: ... small rotary switch with a small screwdriver Valid Device NMEA Instances range from 0 through to F GPS Instance The Gateway connects to the NMEA2000 network and translates messages into the J1939 CANbus network To ensure that only the data from one GPS device on the NMEA2000 network is forwarded to the J1939 CANbus network the GPS Instance switch has to be set to the same Instance as the Device I...

Page 12: ...Indicators Blue LED The left hand side blue LED flashes on NMEA2000 transmits and every 2 5 seconds while receiving valid GPS data Green LED The right hand side green LED flashes only on transmission of J1939 CANbus messages which is every second ...

Page 13: ...e paint or markings or may corrode the enclosure or seals Ensure that the unit is mounted securely and cannot be moved relative to the mounting surface If the unit is loose tighten the mounting screws Check the security of the cables connected to the NMEA2000 connector and the J1939 CANbus connector and tighten as necessary ...

Reviews: