Transition Series

Multi-Technology Access Readers

Description

Transition™ multi-technology card readers feature 
simultaneous compatibility with multi-vendor 125 kHz 
Proximity, Mifare (ISO 14443A), and Vicinity (ISO 15693) 
credential technologies—all in one reader. With this 
remarkable technology combination, security 
administrators can now deploy the Transition readers into 
new or existing facilities.

Figure 1. Multi-technology Readers

Mounting the Reader

All models of the multi-technology series readers can be 
mounted using a U.S. single-gang electrical box or 
directly to a wall. 
1. Find a suitable mounting position on the door frame 

or wall.

Note

: For out of doors or wet locations, it is recom-

mended that the gasket provided be installed on the 
base as shown in Figure 5. 

2. If mounting directly to the wall, use one of the 

following methods: 
2a. Drill two vertical mounting holes from 3.25” 

(83 cm) to 4.891” (125 cm) apart on the mounting 
surface of the door frame or wall. 

Figure 2. Direct wall mounting

2b. Models 520/525 can be mounted using a second 

pair of vertical mounting holes, horizontally 
spaced 2.75” (70 cm) from the first pair. 

Figure 3. T520/525 Direct wall mounting alternative 

3. Drill one 0.625” (15.87 mm) diameter hole in wall for 

the pigtail wire connection.

4. Follow the Cable Connection Chart to connect the 

reader to the field panel and external door 
equipment.

5. Mount the base plate to the wall using the supplied 

screws. 

6. Install gasket if required, see Figure 5.
7. Install the top cover to the reader base. The base 

plate and top cover guides should be aligned, so the 
connectors seat correctly.

Summary of Contents for T-500W

Page 1: ...unted using a U S single gang electrical box or directly to a wall 1 Find a suitable mounting position on the door frame or wall Note For out of doors or wet locations it is recom mended that the gasket provided be installed on the base as shown in Figure 5 2 If mounting directly to the wall use one of the following methods 2a Drill two vertical mounting holes from 3 25 83 cm to 4 891 125 cm apart...

Page 2: ...erify the reader is properly grounded by attaching the ground wire to an earth ground connection at the power supply or field panel end of the cable Connect reader s drain wire to the cable shield Connect shield wires at the field panel The recommended cable gauge is 18 gauge to 22 gauge Check with the cable supplier to determine the best choice for the application and installation distance Testin...

Page 3: ...ion and instructions not expressly approved by UTC Fire Security and is strictly prohibited by the FCC and could void the user s authority to operate the equipment Specifications Colors Black Charcoal Light gray Power supply Linear DC recommended Power usage T 500 210 mA 12 VDC T 520 T 525 130 mA 12 VDC Voltage range 6 16 VDC Temperature rangea a 25 F to 125 F 32 C to 52 C 31 F to 149 F 35 C to 65...

Page 4: ...nting plate for model T 500 470677002 Single Gang Mount plate Charcoal 1 Gang US mounting plate for model T 500 470677003 Single Gang Mount plate Light gray 1 Gang US mounting plate for model T 500 470677001 Dual Gang Mount plate Black 2 Gang US mounting plate for models T 52x 521228001 Dual Gang Mount plate Charcoal 2 Gang US mounting plate for models T 52x 521227001 Dual Gang Mount plate Light g...

Reviews: