background image

Keypad Configuration Card

1. Place the reader in tamper mode by briefly 

removing and replacing the reader’s cover 
while the power is on. The reader stays in 
tamper mode for 60 seconds (minimum) after 
power is applied or the cover is replaced.

2. Present the keypad configuration card within 

one minute. The LED turns green and a short 
triple-beep indicates the reader is ready to 
configure.

3. Enter the keypad entry within five seconds. 

Use the chart below to identify the correct 
keypad entry.

Mode/Keypad entry

Setting

UTC

non-
UTC

1

* followed by 0
(Factory default 
setting)

8 bits per key, no 
buffering. 

2

* followed by 1

6 bits per key, no 
buffering. 

3

# followed by 3 
keys

(0 to 9 only)

26 bits output 
custom 
configuration. 

(Contact Sales 
Engineering/Pre-
Sales Support for 
assistance.)

4

1 followed by 1 
key

(0 to 9 only)

4 bits per key, no 
parity, up to 9 
keys buffered.

5

1 followed by *

4 bits per key, no 
parity, up to 10 
keys buffered.

6

1 followed by #

4 bits per key, no 
parity, up to 11 
keys buffered.

For non-UTC keypad configurations, contact Sales 
Engineering/Pre-Sales Support for assistance.

FCC Compliance

The FCC requires the following statement: This 
reader uses radio frequency energy and has been 
tested, and complies with the limits of FCC testing. 
Changes, modification, or disregard of proper 
installation and instructions not expressly approved 
by UTC Fire & Security, and is strictly prohibited by 
the FCC and could void the user’s authority to 
operate the equipment.

Specifications

Colors

Black, Charcoal, Light gray

Power supply

Linear DC recommended

Power usage

T-500: 210 mA @ 12 VDC
T-520/T-525: 130 mA @ 12 VDC

Voltage range

6 - 16 VDC

Temperature range

a

a. -25°F to 125°F (-32°C to 52°C)

-31°F to 149°F (-35°C to 65°C)

Cable distance to 
panel

Cable Distance 
Max. @ 12 VDC

AWG

200 ft. (60.96 m) 

22

300 ft. (91.44 m) 

20

500 ft. (152.4 m) 

18

Read Range

b

b.

Model T-500W

Vicinity: up to 4.5" (11.43 cm)

Model T-520W and T-525W

Proximity, HID Proximity, and Vicinity: up to 4.5" 
(11.43 cm)

(Distances may vary 
depending on 
environment.)

Proximity Perfect cards are not 
supported by the Transition Series 
reader.

Model T-500W: 

- Proximity: up to 3.5" (8.89 cm)
- HID Proximity: up to 3.5" (8.89 cm)
- Mifare: up to 1" (2.54 cm) 

  Ultralight cards not supported
- Vicinity: up to 5" (12.7 cm)

Model T-520W and T-525W:

- Proximity: up to 5" (15.24 cm)
- HID Proximity: up to 5" (15.24 cm)

-

 Mifare: up to 1" (2.54 cm)

  Ultralight cards not supported
- Vicinity: up to 5" (12.7 cm)

Wiegand output

Proximity 4002 (40-bit)
Mifare 4002 (40-bit)
Vicinity 5502 (55-bit)

Tamper output

Open Collector

Regulatory 
approvals and 
standards

UL 294, CE, and FCC (part 15)

ISO Standards

Mifare ISO 14443A
Vicinity ISO 15693

UL evaluation for UL Listed Installations:

The voltage specification for this reader is 6—16 
VDC, although 12 VDC or greater is recommended 
for better performance and cable run distances.

Summary of Contents for T-500W

Page 1: ...unted using a U S single gang electrical box or directly to a wall 1 Find a suitable mounting position on the door frame or wall Note For out of doors or wet locations it is recom mended that the gasket provided be installed on the base as shown in Figure 5 2 If mounting directly to the wall use one of the following methods 2a Drill two vertical mounting holes from 3 25 83 cm to 4 891 125 cm apart...

Page 2: ...erify the reader is properly grounded by attaching the ground wire to an earth ground connection at the power supply or field panel end of the cable Connect reader s drain wire to the cable shield Connect shield wires at the field panel The recommended cable gauge is 18 gauge to 22 gauge Check with the cable supplier to determine the best choice for the application and installation distance Testin...

Page 3: ...ion and instructions not expressly approved by UTC Fire Security and is strictly prohibited by the FCC and could void the user s authority to operate the equipment Specifications Colors Black Charcoal Light gray Power supply Linear DC recommended Power usage T 500 210 mA 12 VDC T 520 T 525 130 mA 12 VDC Voltage range 6 16 VDC Temperature rangea a 25 F to 125 F 32 C to 52 C 31 F to 149 F 35 C to 65...

Page 4: ...nting plate for model T 500 470677002 Single Gang Mount plate Charcoal 1 Gang US mounting plate for model T 500 470677003 Single Gang Mount plate Light gray 1 Gang US mounting plate for model T 500 470677001 Dual Gang Mount plate Black 2 Gang US mounting plate for models T 52x 521228001 Dual Gang Mount plate Charcoal 2 Gang US mounting plate for models T 52x 521227001 Dual Gang Mount plate Light g...

Reviews: