background image

Lonworks (ACP Lonworks)

PLNWKB000 
Original instructions  

INSTALLATION MANUAL

AIR

CONDITIONER

Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring 
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.

MFL69157004

Rev.00_050819

www.lg.com

Copyright © 2015 - 2019 LG Electronics Inc. All Rights Reserved.

ENGLISH

POR

TUGUÊS

MAL

TI

MA

G

Y

AR

SLOVENČINA

БЪЛГАРСKN

SL

O

VENŠČINA

SRPSKI

LA

TVIEŠU V

AL

OD

A

HR

V

A

T

SKI

LIETUVIŲ KALBA

S

VENSKA

GAEIL

GE

NORSK

МАКЕДОНСКИ

SUOMI

SHQIP

D

ANSK

ÍSLENSKA

EESTI KEEL 

BOSANSKI

IT

ALIANO

ESP

AÑOL

FRANÇAIS

DEUTSCH

ΕΛΛΗΝΙΚΆ

ČEŠTINA

NEDERL

ANDS

POL

SKI

LIMBA ROMÂNĂ

Summary of Contents for V-NET PLNWKB000

Page 1: ...ersonnel only Please retain this installation manual for future reference after reading it thoroughly MFL69157004 Rev 00_050819 www lg com Copyright 2015 2019 LG Electronics Inc All Rights Reserved ENGLISH PORTUGUÊS MALTI MAGYAR SLOVENČINA БЪЛГАРСKN SLOVENŠČINA SRPSKI LATVIEŠU VALODA HRVATSKI LIETUVIŲ KALBA SVENSKA GAEILGE NORSK МАКЕДОНСКИ SUOMI SHQIP DANSK ÍSLENSKA EESTI KEEL BOSANSKI ITALIANO ES...

Page 2: ...the product is damp it may malfunction For installation of the product please contact the dealer from where you purchased the product or a service center Installation of the product by an unauthorized person may result in fire electric shock explosion injury or a malfunctioning of the product For electrical work please have an electrician do the work based on the installation manual and specified ...

Page 3: ...rdian Carelessness may cause an accident or the product to malfunction The guardian should prevent children from accessing the product The product may be damaged or it may fall causing injury to children Keep in mind the operating temperature range specified in the manual If there is no operating tempera ture range in the manual use the product between 0 C and 40 C 32 F and 104 F If the product is...

Page 4: ...sen causing injury to the user Do not leave the product near a flower base water bottle or any other liquids It may cause a fire or electric shock If the liquid crystal of the product is broken please do not let your skin such as face or hands contact with Personal injury or property damage may occur Transformer selection Select an insulating product that complies with IEC61558 2 6 and NEC Class 2...

Page 5: ...e 2002 96 EC 2 All electrical and electronic products should be disposed of sepa rately from the municipal waste stream via designated collection fa cilities appointed by the government or the local authorities 3 The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health 4 For more detailed information about disposal of your ol...

Page 6: ...nworks are as follows Controlling of up to 64 air conditioner indoor units Monitoring of error and operation status Controlling the peak power demand power System setting function ACP Lonworks Components Inside the packaged box of the ACP Lonworks there are the components as in the following drawing Open the packaged box of the ACP Lonworks and check if all of the corresponding components are incl...

Page 7: ...rmation Basic external input output signal connectors Connection ports to connect to external input output sig nals DI 2 DO 2 RS 485 communication port RS 485 communication ports to connect to air conditioner and ERV equipment 4 in total RS 485 LON communica tion ports and BMS connec tion button SERVICE SWITCH RS 485 communication ports 2EA and LON comunication port 1EA BMS connection button SERVI...

Page 8: ...ther settings STEP 6 Set ACP Lonworks network address Set the network address to be able to access the ACP Lonworks through internet STEP 7 Set ACP Lonworks functions Set language peak demand whether to use schedule whether to use power display etc STEP 8 Set ACP Lonworks module type Set connected product type STEP 9 Set Web GUI access environment Set the access environment in Web GUI which is the...

Page 9: ...ne RS 485 port and up to 31 PI485 for SINGLE ventilation can be connected The number of the indoor units that can be connected to one ACP Lonworks One ACP Lon works can be connected up to 64 indoor units To one RS 485 port all of 64 indoor units which is the maximum number that can be con nected to the ACP Lonworks may be connected But to improve the communication performance of RS 485 it is recom...

Page 10: ... the entire installation configuration connecting to one ACP Lonworks set the ad dress to each indoor unit not to be overlapped Address range that can be set to indoor units are determined as selected module type Module 0 00 FF in hexadecimal can be set to the indoor unit address but it can be connected up to 64 indoor units only Module 1 00 0F in hexadecimal can be set to the AHU unit address and...

Page 11: ... DIN RAIL Decide the space to install the ACP Lon works Before installing the ACP Lonworks check if it is the adequate place to connect the ACP Lonworks with the power RS 485 and LAN LON cables Install DIN RAIL Hook the top part of the ACP Lonworks on DIN RAIL Push the main body of the ACP Lonworks until you hear the sound of installation Pull the ACP Lonworks to check if it is fixed Power LAN cab...

Page 12: ...d to BUS B of PI485 to Rx part RS 485 cable that was connected to PI485 shall be connected to CH port RS 485 port of the ACP Lonworks Plug the connector connecting RS 485 cable into one of CH1 CH4 ports There are CH1 CH6 ports and it must be plugged into one of CH1 CH4 ports for use For AHU plug the connector connecting RS 485 cable into CH5 ports For chiller plug the connector connecting RS 485 c...

Page 13: ...ng the ACP Lonworks to various devices via the cable the network environ ment of the ACP Lonworks should be set by driving the ACP Lonworks The following information should be set for using the ACP Lonworks IP address of the ACP Lonworks Gateway address Net mask Connection with hub Direct cable Direct connection with PC Cross cable ON OFF ON OFF PLNWKB000 BMS Control PC Lonworks Adaptor POWER ON O...

Page 14: ...work information such as IP address of the ACP Lonworks When you select Function and press SET button it enters the No 2 menu in the following figure In Function menu ACP Lonworks software service function is supported In LON GW Info menu you can set the module type of the ACP Lonworks as connected product Wait for booting ACP Lonworks SW ver 1 0 0 I P 192 168 001 100 GW 192 168 001 001 NOTE Softw...

Page 15: ...BMS After connecting with Lonworks BMS Lonworks Building Management System press Service Switch of ACP Lonworks Then Service LED will be turned on and the Neuron ID will be sent to Lonworks BMS Check that Service LED is changed to normal condition LED OFF within 10 minutes If Service LED is change to normal condition it is installed normally ...

Page 16: ...cally to use the functionality of the various content I can The Manual I will explain to Central Controller standard equipment Login You can login as follows 1 Run Central Controller 2 After entering your ID and password in the login window click touch Confirm You should be logged in now Logout You can logout as follows 1 On the top right of the Central Controller home screen click touch the Logou...

Page 17: ...GUI does not run Please check LAN cable and the power supply of Hub Indoor remote control does not work ACP Lonworks in the lock feature is enabled the remote con trol function is not set Peak control state must function setting from the remote control at the indoor unit If the function is active set the time schedule may be disabled I would like to change the name of the indoor unit Log in as sup...

Page 18: ...18 ENGLISH ...

Page 19: ...esentative LG Electronics Inc EU Representative Krijgsman 1 1186 DM Amstelveen The Netherlands Manufacturer LG Electronics Inc Changwon 2nd factory 84 Wanam ro Seongsan gu Changwon si Gyeongsangnam do KOREA ...

Reviews: