7B-77 Air Conditioning System: Automatic Type
G20-8
BLU/WHT
Electric load signal for
blower motor
10 – 14 V
• Ignition switch turned ON, blower speed selector
OFF or 1st position
• Ignition switch turned ON, blower speed selector
from 1st to 2nd position
0 – 2 V
• Ignition switch turned ON, blower speed selector
between 3rd and HIGH position
• Ignition switch turned ON, blower speed selector
from 3rd to 2nd position
G20-9
WHT/BLK
Evaporator temperature
sensor signal
Approx. 2.6 V
Ignition switch turned ON, evaporator temperature 0
°
C (32
°
F)
Approx. 1.7 V
Ignition switch turned ON, evaporator temperature
15
°
C (59
°
F)
Approx. 1.0 V
Ignition switch turned ON, evaporator temperature
30
°
C (86
°
F)
G20-10
PNK/BLK
Inside air temperature
sensor signal
Approx. 2.5 V
Ignition switch turned ON, room temperature 25
°
C
(77
°
F)
Approx. 3.7 V
Ignition switch turned ON, room temperature 0
°
C
(32
°
F)
G20-11
—
—
—
G20-12
WHT
Output of 5 V power
source for air flow control
actuator position sensor
and temperature control
actuator position sensor
4 – 6 V
Ignition switch turned ON
G20-13
YEL
Serial communication line
of BCM
Refer to “Reference waveform No. 2: Automatic Type”.
G20-14
—
—
—
—
G20-15 BRN/YEL
Air flow control actuator
(FACE)
10 – 14 V
Ignition switch turned ON, air flow control actuator is
working in operation from “DEF” to “FACE” position
0 – 1 V
Ignition switch turned ON, except the above
condition
G20-16 BRN/WHT
Air flow control actuator
(DEF)
10 – 14 V
Ignition switch turned ON, air flow control actuator is
working in operation from “FACE” to “DEF” position
0 – 1 V
Ignition switch turned ON, except the above
condition
G20-17
GRN
Air intake actuator
(FRESH AIR)
0 – 1 V
Ignition switch turned ON, air intake selector “FRE”
position
10 – 14 V
Ignition switch turned ON, air intake selector “REC”
position
G20-18
RED
Air intake actuator
(RECIRCULATION AIR)
0 – 1 V
Ignition switch turned ON, air intake selector “REC”
position
10 – 14 V
Ignition switch turned ON, air intake selector “FRE”
position
G20-19 GRN/RED
Air intake actuator (MIX
AIR)
10 – 14 V
Ignition switch turned ON, air intake selector “FRE”
or “REC” position
0 – 1 V
Ignition switch turned ON, air intake selector is
working in operation from “FRE” to “REC” or “REC”
to “FRE” position
G20-20
—
—
—
—
G20-21 GRN/WHT A/C switch signal
Refer to “Reference waveform No. 1: Automatic Type”.
G20-22 RED/BLK Electric power source
10 – 14 V
Ignition switch turned ON
G20-23 BLK/ORN
Ground for HVAC control
module
Below 0.5 V Ignition switch turned ON
G20-24
ORN
Ground for sensors
Below 0.5 V Ignition switch turned ON
Terminal Wire Color
Circuit
Normal
Voltage
Condition
Summary of Contents for 2006 SX4
Page 2: ......
Page 6: ......
Page 22: ...00 15 Precautions...
Page 38: ...0B 7 Maintenance and Lubrication...
Page 378: ...1K 6 Exhaust System...
Page 848: ...6C 46 Power Assisted Steering System...
Page 954: ...7B 89 Air Conditioning System Automatic Type...
Page 1086: ...8B 121 Air Bag System...
Page 1381: ...Paint Coatings 9L 7 I5RW0C9C0005 01 A Apply sealant 1 Hole...
Page 1382: ...9L 8 Paint Coatings I5RW0C9C0006 01 A Apply sealant covering flange end...
Page 1476: ...Prepared by 1st Ed Feb 2007...