Air Conditioning System: Automatic Type 7B-52
)
B1521
Blower Speed
Selector
Malfunction
16
1
Signal voltage of blower speed selector in HVAC
control module is higher than specification.
Flashed
16
2
Signal voltage of blower speed selector in HVAC
control module is lower than specification.
Flashed
)
B1522
Air Flow Selector
Malfunction
17
1
Signal voltage of airflow selector in HVAC control
module is higher than specification.
Flashed
17
2
Signal voltage of airflow selector in HVAC control
module is lower than specification.
Flashed
)
B1541
Back-up Power
Supply Circuit
Malfunction
14
1
• Back-up power supply voltage of HVAC control
module is higher than or lower than
specification.
• When connect battery with vehicle and then,
turn ignition switch to ON position for first time.
—
)
B1546
A/C Refrigerant
Pressure
Malfunction
13
5
• Signal voltage of outside air temperature sensor
is more than specified value. However, A/C
refrigerant pressure is less than specified value.
• Insufficient refrigerant in A/C system.
—
)
B1551
Serial
Communication
Circuit
Malfunction
9
1
Circuit voltage of serial communication circuit is
higher than specification.
Flashed
9
2
Circuit voltage of serial communication circuit is
lower than specification.
Flashed
)
B1552
HVAC Control
Module Check
Sum Error
9
4
HVAC control module received unspecified data
from BCM more than 8 times.
Flashed
)
B1553
CAN
Communication
Circuit
Malfunction
10
4
HVAC control module received signal indicating
reception error from ECM.
Flashed
)
B1557
VSS Signal
Failure
11
4
HVAC control module receives invalid data of VSS
signal from BCM.
—
)
B1561
ECT signal
Failure
5
4
HVAC control module receives invalid data of ECT
signal from BCM.
Flashed
)
B1562
Outside
Temperature
Sensor Signal
Failure
1
4
HVAC control module receives invalid data of
outside air temperature sensor signal from BCM.
Flashed
)
B1563
A/C Refrigerant
Pressure Sensor
Signal Failure
13
4
HVAC control module receives invalid data of A/C
refrigerant pressure sensor signal from BCM.
—
)
B1570
Engine Type
Signal Failure
20
4
HVAC control module receives invalid data of
engine type signal from BCM.
—
)
B1571
Combination
Meter Spec
Signal Failure
21
4
HVAC control module receives invalid data of
combination meter spec signal from BCM.
—
NO CODE
Normal
See NOTE below
—
—
DTC No.
(displayed
on SUZUKI
scan tool)
Detection item
DTC (indicated on
HVAC control
module)
Condition when trouble detected (DTC is
determined when following condition detected)
“A/C”
indicator
light
Indicated
by “REC”
indicator
light
Indicated
by “FRE”
indicator
light
Summary of Contents for 2006 SX4
Page 2: ......
Page 6: ......
Page 22: ...00 15 Precautions...
Page 38: ...0B 7 Maintenance and Lubrication...
Page 378: ...1K 6 Exhaust System...
Page 848: ...6C 46 Power Assisted Steering System...
Page 954: ...7B 89 Air Conditioning System Automatic Type...
Page 1086: ...8B 121 Air Bag System...
Page 1381: ...Paint Coatings 9L 7 I5RW0C9C0005 01 A Apply sealant 1 Hole...
Page 1382: ...9L 8 Paint Coatings I5RW0C9C0006 01 A Apply sealant covering flange end...
Page 1476: ...Prepared by 1st Ed Feb 2007...