Air Conditioning System: Automatic Type 7B-46
A/C System Symptom Diagnosis
S6RW0C7224002
Condition
Possible cause
Correction / Reference Item
No cool air comes out (A/
C system does not
operate)
No refrigerant
Perform recovery, evacuation and charge
referring to “Operation Procedure for
Refrigerant Charge”.
Fuse blown
Check related fuses, and then check for short
circuit to ground.
A/C switch faulty
Check A/C switch referring to “Inspection of
HVAC Control Module and Its Circuit”.
Evaporator temperature sensor faulty
Check evaporator temperature sensor
referring to “Evaporator Temperature Sensor
Inspection”.
A/C refrigerant pressure sensor faulty
Check A/C refrigerant pressure sensor
referring to “A/C Refrigerant Pressure Sensor
and Its Circuit Inspection”.
Wiring or grounding faulty
Repair as necessary.
ECM faulty
Check ECM referring to “A/C System
Inspection at ECM”.
HVAC control module faulty
Check HVAC control module referring to
“Inspection of HVAC Control Module and Its
Circuit”.
Magnet clutch faulty
Check magnet clutch referring to “Magnet
Clutch Inspection”.
Compressor drive belt loosened or
broken
Adjust or replace drive belt.
Compressor faulty
Check compressor.
Compressor relay faulty
Check compressor relay referring to “A/C
System Relay Inspection”.
BCM faulty
Check BCM referring to “Inspection of BCM
and Its Circuits in Section 10B”.
No cool air comes out
(radiator cooling fan
motor does not operate)
Fuse blown
Check related fuses, and then check for short
circuit to ground.
Wiring or grounding faulty
Repair as necessary.
Condenser cooling fan motor relay faulty
Check condenser cooling fan motor relay
referring to “A/C System Relay Inspection”.
Condenser cooling fan motor faulty
Check condenser cooling fan motor referring to
“Condenser Cooling Fan Inspection”.
ECM faulty
Check ECM referring to “A/C System
Inspection at ECM”.
HVAC control module faulty
Check HVAC control module referring to
“Inspection of HVAC Control Module and Its
Circuit”.
No cool air comes out
(blower motor does not
operate)
Fuse blown
Check related fuses, and then check for short
circuit to ground.
Blower motor controller faulty
Check blower motor controller referring to
“Blower Motor Controller Inspection”.
HVAC control module faulty
Check HVAC control module referring to
“Inspection of HVAC Control Module and Its
Circuit”.
Wiring or grounding faulty
Repair as necessary.
Blower motor faulty
Check blower motor referring to “Blower Motor
Inspection in Section 7A”.
Blower motor relay faulty
Check blower motor relay referring to “Blower
Motor Relay Inspection in Section 7A”.
Summary of Contents for 2006 SX4
Page 2: ......
Page 6: ......
Page 22: ...00 15 Precautions...
Page 38: ...0B 7 Maintenance and Lubrication...
Page 378: ...1K 6 Exhaust System...
Page 848: ...6C 46 Power Assisted Steering System...
Page 954: ...7B 89 Air Conditioning System Automatic Type...
Page 1086: ...8B 121 Air Bag System...
Page 1381: ...Paint Coatings 9L 7 I5RW0C9C0005 01 A Apply sealant 1 Hole...
Page 1382: ...9L 8 Paint Coatings I5RW0C9C0006 01 A Apply sealant covering flange end...
Page 1476: ...Prepared by 1st Ed Feb 2007...