Air Conditioning System: Automatic Type 7B-60
DTC B1504: Sunload Sensor Circuit Malfunction
S6RW0C7224012
Wiring Diagram
DTC Detecting Condition and Trouble Area
NOTE
When DTC B1502, B1503, B1511 and B1512 are indicated together, it is possible that sensor ground
circuit is open.
3
Evaporator temperature sensor reference voltage check
1) Connect connector to HVAC control module with ignition
switch turned OFF.
2) Turn ignition switch to ON position.
3) Measure voltage between signal terminal and ground
terminal of evaporator temperature sensor connector.
Is voltage 4.5 – 5.5 V?
Go to Step 4.
Substitute a known-
good HVAC control
module and recheck.
4
Evaporator temperature sensor check
1) Check evaporator temperature sensor for performance
referring to “Evaporator Temperature Sensor
Inspection”.
Is it in good condition?
Substitute a known-
good HVAC control
module and recheck.
Replace evaporator
temperature sensor.
Step
Action
Yes
No
G20
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
24
23
22
25
26
27
28
29
30
PNK
ORN
ORN
G20-25
G20-24
2
[S]
[G]
1
5V
3
I7RW01722006-01
[S]: Sunload sensor signal circuit
1. HVAC control module
3. To other sensors
[G]: Sunload sensor ground circuit
2. Sunload sensor
DTC Detecting Condition
Trouble Area
• Sunload sensor signal voltage is higher than or lower than specified value
for specified time continuously.
• Without sunlight
• Sunload sensor circuit
• Sunload sensor
• HVAC control module
Summary of Contents for 2006 SX4
Page 2: ......
Page 6: ......
Page 22: ...00 15 Precautions...
Page 38: ...0B 7 Maintenance and Lubrication...
Page 378: ...1K 6 Exhaust System...
Page 848: ...6C 46 Power Assisted Steering System...
Page 954: ...7B 89 Air Conditioning System Automatic Type...
Page 1086: ...8B 121 Air Bag System...
Page 1381: ...Paint Coatings 9L 7 I5RW0C9C0005 01 A Apply sealant 1 Hole...
Page 1382: ...9L 8 Paint Coatings I5RW0C9C0006 01 A Apply sealant covering flange end...
Page 1476: ...Prepared by 1st Ed Feb 2007...