Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
26
0x2029
Torque
Command
Resonance Filter
Depth
dB
-100~100
0
Immediately
Parameter Description:
User permission:
User/Engineer
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
27
0x202A
Actual Torque Current Low-pass
Filter Cutoff Frequency
Hz
800~8000
8000
Immediately
Parameter Description:
User permission:
User/Engineer
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
68
0x2070
Torque Command Resonance
Filter Center Frequency
0.1Hz
10~10000
100
Immediately
Parameter Description:
User permission:
User/Engineer
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
69
0x2071
Torque Command Resonance
Filter Bandwidth
0.1Hz
1~1000
10
Immediate
ly
Parameter description:
Set the torque command resonance filter bandwidth.
User permission:
User/Engineer
Parameter permission:
Read and Write
175
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...