Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
6.3.1.2
Event Description
The following table lists the specific meanings of the drive's state transition triggering events.
Table 7.3-1.
Description of transition triggering events
State·switch·
serial·
number
Condition
Motion
0
Automatic execution after power-on or reset
Drive self-test and initialization
1
The drive self-test and initialization have
completed correctly
Activate communication function
2
Received Shutdown command
None
3
Received Switch On command and AC contactor
has already closed
After the DC bus charging has completed, close the
pre-charge relay switch
4
Received Enable Operation command and the
pre-charge relay has closed
Enable motor output
5
Received Disable Operation command and
0x605C=0
Disable motor output
5'
Received Disable Operation command and
0x605C=1
Select the controlled stop mode and execute
5"
Controlled stop completed
Disable motor output
6
Received Shutdown command
Disconnect the pre-charge relay switch
7
Received Quick Stop or Disable voltage command None
8
Received Shutdown command and 0x605B=0
Disable motor output and disconnect the pre-charge relay
switch
8'
Received Shutdown command and 0x605B=1
Select the controlled stop mode and execute
8"
Controlled stop completed
Disable motor output and disconnect the pre-charge relay
switch
9
Received Disable voltage command
Disable motor output and disconnect the pre-charge relay
switch
10
Received Quick Stop or Disable voltage command Disconnect the pre-charge relay switch
11
Received Quick Stop command and 0x605A != 0
Select the controlled stop mode and execute
11'
Received Quick Stop command and 0x605A = 0
Disable motor output and disconnect the pre-charge relay
switch
12
Controlled stop completed and 0x605A != 0, or
received Disable voltage command
Disable motor output and disconnect the pre-charge relay
switch
13
Fault occurs
Select the stopping mode and record historical faults
14
Stopped successfully
Disable motor output
15
Received Fault Reset command
Disconnect the pre-charge relay switch and clear the fault
flag if the fault causes have been eliminated
47
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...