Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
93
0x20C7
Motor Pole Pairs
Number
-
1~100
4
Restart
Parameter description:
Set the motor pole pairs number, for example: 0x20C7=2, indicating a 4-pole motor.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
158
0x20C8
Motor torque
constant
mN.m/A
1~
2147483647
2290
Restart
Parameter description:
Set the motor torque constant, which is provided by the motor manufacturer.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
159
0x20C9
Motor thermal
time constant
sec
60~
3600
1100
Restart
Parameter description:
Set the motor thermal time constant, which is provided by the motor manufacturer.
User permission:
User/Engineer.
Parameter permission:
Read only
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
121
0x6072 Max motor torque
‰TN
1~10000
3000
Immediate
ly
Parameter description:
Set the maximum allowable torque of a servo motor, which is a permillage of the
rated torque.
User permission:
User/Engineer.
Parameter permission:
Read and Write
110
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...