Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
5.2.3.2
Relevant Parameters:
0x2080 Velocity Profile Type
Byte0: Velocity Profile Type
0x00-TTV0
0x01-Simple Continuous Mode TTV1
0x02-Programming Continuous Mode TTV2
0x03-Programming Continuous Mode TTV3
0x04-Programming Continuous Mode STV
0x210B Jog Slow Speed
0x210C Jog Fast Speed
0x210D Jog Acceleration Time
0x2100 Program Pulse Speed
0x2101 Program Pulse Wait Time
0x2102 Program Pulse UpTime
0x2103 Program Pulse Down Time
0x2104 Program Pulse Duration Time
0x2105 Program Pulse Loop Count
0x2106 Program Sin Peak Speed
0x2107 Program Sin Offset Speed
0x2108 Program Sin frequency
Trial Operation Under PT Mode
5.2.4
So far, there are four ways of PT mode trial operation of DriveStarter host commissioning software, including
Simple Torque Profile (TTT1), Programming Torque Profile 1 (TTT2), Programming Torque Profile 2 (TTT3) and
Sinusoidal Torque Profile (STT).
5.2.4.1
Diagram of Trial Operation Under PT Mode:
Figure 5.2-6 Diagram of Simple Torque Profile (TTT1)