Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
1)
As for users who need braking through external energy consumption, the following three parameters must
be set correctly:
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
34
0x2034
Regenerative
Resistor Power
Watt
400~65535
1000
Restart
Parameter description:
External brake resistor power, which should be set consistently with the actual value
in real application.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
35
0x2035
Resistance of
Regenerative
Resistor
Ohm
65~65535
65
Restart
Parameter description:
External brake resistance, which should be set consistently with the actual value in
real application.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
36
0x2037
Regenerative
Braking Resistor
De-rating Factor
%
1~ 100
100
Restart
Parameter description:
This parameter provides the de-rating factor of the regenerative braking resistor.
User permission:
User/Engineer.
Parameter permission:
Read and Write
118
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...