Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
0x202F Motor Operation Environment
Index
0x202F
Object type
VAR
Name
Motor Operation Environment
Sub-index
PDO
mapping
Read and write
operations
Data type
Unit
Description
0x00
NO
rw
UINT32
-
Motor Operation Environment
Set the motor operation environment
Byte0-cooling method
0x00-Natural cooling
0x01-Forced air cooling
Byte1-Mounting method
0x00-Suspended mounting
0x01-Substrate-mounted
Byte2-Mounting space
0x00-Confined space
0x01-Open space
Byte3-Heat radiation level of the motor
0x00-Level 0
0x01-Level 1
0x02-Level 2
0x03-Level 3
0x04-Level 4
0x05-Level 5
0x06-Level 6
0x20A6 Motor Overload Warning Level
Index
0x20A6
Object type
VAR
Name
Motor Overload Warning Level
Sub-index
PDO
mapping
Read and write
operations
Data type
Unit
Description
0x00
NO
rw
UINT16
%
Motor Overload Warning Threshold
When the motor load is over the set value, the drive alarms.
The STA
indicator flashes red and green and the drive keeps
running.
0x20C0 Motor Rated Power
Index
0x20C0
Object type
VAR
Name
Motor Rated Power
Sub-index
PDO
mapping
Read and write
operations
Data type
Unit
Description
0x00
NO
rw
UINT32
Watt
Motor Rated Power
Set the motor rated power. This parameter is provided by the manufacturer.
69
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...