background image

P5-20...L120-11

Model: C16

en

Assembly and Operating Instructions

Radio controlled sun protection drives with locking

system

Important information for:

• Fitters / • Electricians / • Users

Please forward accordingly!

These instructions must be kept safe for future reference.

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

2010 300 981 0     26/01/2022   

Содержание C16

Страница 1: ...tection drives with locking system Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 981 0 26 01 2022 ...

Страница 2: ...itions 13 Intermediate position I in the down direction 13 Intermediate position II in the up direction 14 Programming additional transmitters 14 Deleting transmitters 15 Overwriting the master 16 Local operation with a single button 17 Programming and deleting the run times 18 Programming the run times 18 Deleting the run times 18 Activating deactivating the additional fabric untensioning functio...

Страница 3: ...nd setting the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 34th calendar week in 2020 Ser No 2034XXXXX Explanation of pictograms CAUTION CAUTION indicates a hazardous situation which if not avoided could result in injury ATTENTION ATTENTION indicates measures...

Страница 4: ...f safety instructions is not exhaustive since it would be impossible for the standard to include all sources of danger For example the design of the operated product the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user s place of use cannot be taken into consideration by the drive manufacturer If any questions or uncertainties regar...

Страница 5: ...y unit are live Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings Be careful when touching the tubular drive as it heats up during operation for technical reasons Before installation shut down all lines and control devices that are not essential for op eration Crushing or shearing points must be avoided or protected When insta...

Страница 6: ... can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liability for damage or injury resulting from improper usage Assembling and disas...

Страница 7: ...he enclosed connection information to the responsible electrical contractor Calculate the space required at the side M by measuring the drive head 1 and wall bracket 2 The clear dimension of the box X minus the space required at the side M and idler G gives the length L of the barrel L X M G The space required at the side M varies depending on the combination of drive and wall bracket Then mount t...

Страница 8: ...mm To ensure secure torque transmission for round shafts we recommend screwing the drive adapter to the shaft see the table below Attention When drilling into the barrel never drill near the tubular drive Size of drive mm Drive adapter Torque max Nm Fastening screws 4 units dia 35 dia 45 All Up to 50 Self tapping screw dia 4 8 x 9 5 mm dia 58 Aluminium drive adapter Up to 120 Countersunk screw M8 ...

Страница 9: ...Lay the connecting cable Lay the connecting cable up to the tubular drive and fix The connecting cable and any antennae must not project into the winding chamber Cover any sharp edges 9 en ...

Страница 10: ...of the sun protection sys tem N 1 2 1 2 4 3 4 230V AC 50 Hz L1 PE Connecting the tubular drive Connect the tubular drive to the power supply 1 blue 3 black 2 brown 4 green yellow Readying the tubular drive for programming Readying the tubular drive for programming by switching on the power Switch on the power The tubular drive is ready to programme for 3 minutes If several tubular drives are to be...

Страница 11: ...mming button for 10 seconds Checking that the running direction is correct The direction of rotation can only be changed if no limit position has been set There are several ways to change the direction of rotation Changing direction of rotation via the direction switch Changing direction of rotation via master transmitter Changing direction of rotation via the direction switch Press the or button ...

Страница 12: ...eriod the sys tem is ready for operation again The drive does not achieve its full duty cycle until it has cooled to ambient temperature Avoid a situation where the thermal protection switch cuts in repeatedly The limit positions can only be set with the master transmitter The shutter direction must be correct When setting the limit positions the tubular drives runs in dead man mode If the tubular...

Страница 13: ...imit positions are now deleted Intermediate position I in the down direction The intermediate position I is any shading solution position of your choosing It is not pos sible to set an intermediate position I in the area of the limit position Both limit positions must be set before the intermediate position I is set When both limit positions are deleted this set function is deleted as well Setting...

Страница 14: ...e position II 2x Move the shading solution to the intermediate position II Press the STOP button and within 3 seconds also press the UP button and hold the two buttons down The tubular drive acknowledges The intermediate position II is now deleted Programming additional transmitters In addition to the master transmitter up to 15 further transmitters can be programmed in the tubular drive Before pr...

Страница 15: ...ogramming button of the transmitter to be deleted again for 10 seconds The tubular drive acknowledges The transmitter is now deleted from the tubular drive Deleting all transmitters except the master transmitter 3s Press the programming button on the master transmitter for 3 seconds The tubular drive acknowledges 3s Re press the programming button on the master transmitter for 3 seconds The tubula...

Страница 16: ...e and back to the outside position N 1 2 1 2 4 3 4 230V AC 50 Hz L1 PE Switch off the tubular drive power for 5 seconds then switch it back on The tubular drive is ready to program for 3 minutes 1 blue 3 black 2 brown 4 green yellow 10s Now press the programming button of the new master transmitter for 10 seconds The tubular drive acknowledges The new master transmitter has now been programmed and...

Страница 17: ...tton must not be operated during the first five seconds after the mains voltage has been switched on N L PE Button normally open black brown blue green yellow Button commands 1 second Moves in maintained operation 1 second Moves in dead man mode Double tap 1 second Moves to the intermediate position in alternation if both are programmed Operation proceeds in this sequence Travel Stop Travel in the...

Страница 18: ... limit position 4 Release the direction button The tubular drive has saved the current time for this direction of travel Deleting the run times When deleting both run times are always deleted To delete the retract and extend run time press the STOP button for 10 seconds The tubular drive makes a click click sound to confirm The run times are now deleted Activating deactivating the additional fabri...

Страница 19: ...mm 37 Frequency 868 3 MHz Emission sound pressure level dB A 70 Technical data dia 45 Tubular drive R8 17 R12 17 R20 17 R30 17 R40 17 Model C16 Type C SEF I2 Rated torque Nm 8 12 20 30 40 Output speed rpm 17 17 17 17 17 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 100 110 160 205 260 Rated current consumption A 0 45 0 50 0 75 0 90 1 15 Operating mode S2 4 min De...

Страница 20: ...n switch in tubular drive has tripped Wait until the thermal protection switch in the tubular drive is reactivated Running direction on tubular drive cannot be set Delete limit positions see chapter Deleting limit positions and reset the running direction Incorrect running direction after deleting limit positions Use the master transmitter or the direction switch on the tubular drive to change the...

Страница 21: ...Declaration of conformity 21 en ...

Страница 22: ...22 ...