Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
0x10 - Disable the current regulator adaptive control, enable the velocity regulator adaptive control
0x11 - Enable the current regulator adaptive control, enable the velocity regulator adaptive control
Parameter Description:
CoolDrive R series drives don't support current regulator adaptive control
temporarily.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
58
0x204F
Current Regulator Inflection
Current 1
‰IN
1~2000
1000
Immediately
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
59
0x2050
Current Regulator
Inflection Current 2
‰IN
1~4000
2000
Immediately
Parameter description:
Only if the current regulator adaptive control of Byte3 in 0x2065 is enabled, current
regulator inflection current 1 and 2 are valid. For detailed information about the current regulator adaptive control,
please refer to the figure below, "Diagram of torque PI gain automatic switching". IN is the rated current.
User permission:
User/Engineer
Parameter permission:
Read and Write
Diagram of torque PI gain automatic switching:
Figure 7.10-1.
Diagram of torque PI gain automatic switching
177
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...