Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
122
0x6073 Max motor current
‰IN
1~10000
3000
Immediate
ly
Parameter description:
Set the maximum allowable current of a servo motor, which is a permillage of the
rated current. For detailed values, please refer to the motor's technical manuals.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
123
0x6075
Motor rated
current
mA
1~2147483647
4000
Restart
Parameter description:
Set the rated current of a motor with a specific voltage class.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
124
0x6076 Motor rated torque
mNm
1~2147483647
3000
Restart
Parameter description:
Set the rated motor torque.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
128
0x6080
Maximum motor
speed
r/min
1~20000
6000
Immediate
ly
Parameter description:
Set the maximum allowable speed of a motor, which should not exceed the highest
speed given by the motor manufacturer, in order to protect the motor.
User permission:
User/Engineer.
Parameter permission:
Read and Write
111
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...