Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
135
0x60C6
Max
deceleration
inc/ms²
1~2147483647
2147483647 Immediately
Parameter Description:
User permission:
User/Professional.
Parameter permission:
Read and Write
Square Wave Speed Setting
7.9.3
Square wave speed setting mainly introduces parameters related to TTV2 and TTV3 in the commissioning of
DriveStarter. Details can be found in Section 6.2.3.
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
97
0x2100
Set Speed of
Square Wave
r/min
1~10000
100
Immediately
Parameter description:
Set the square wave speed of PV-TTV2 and PV-TTV3.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
98
0x2101
Program Pulse
Wait Time
ms
0~65535
1000
Immediately
Parameter description:
This parameter applies to mode PV-TTV2, PV-TTV3, PT-TTT2 and PT-TTT3.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
99
0x2102
Program Pulse
up time
ms
0~65535
1000
Immediately
Parameter description:
This parameter is used to set speed rise time of PV-TTV2 and PV-TTV3.
User permission:
User/Engineer/Designer.
Parameter permission:
Read and Write
155
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...