Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
0x12-No index pulse homing 2;
0x13-No index pulse homing 3;
0x14-No index pulse homing 4;
0x15-No index pulse homing 5;
0x16-No index pulse homing 6;
0x17-No index pulse homing 7;
0x18-No index pulse homing 8;
0x19-No index pulse homing 9;
0x1A-No index pulse homing 10;
0x1B-No index pulse homing 11;
0x1C-No index pulse homing 12;
0x1D-No index pulse homing 13;
0x1E-No index pulse homing 14;
0x1F~0x20-Reserved;
0x21-Index pulse homing 1;
0x22-Index pulse homing 2;
0x23-Current position homing;
0x24-Touch probe homing.
Byte1: Reserved. The default value is 0
Parameter Description:
User permission:
User/Professional.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
133
0x609A
Homing
acceleration
inc/ms²
1~65535
20
Immediately
Parameter permission:
Set the homing acceleration and deceleration.
User permission:
User/Professional.
Parameter permission:
Read and Write
PP Mode Parameters
7.8.4
Below are point-to-point parameters in DriveStarter commissioning.
142
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...