Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
0x01 - Enable the current prediction control
Byte3: Regulator adaptive control
0x00 - Disable all the regulator adaptive control
0x01 - Enable the current regulator adaptive control, disable the velocity regulator adaptive control
0x10 - Disable the current regulator adaptive control, enable the velocity regulator adaptive control
0x11 - Enable the current regulator adaptive control, enable the velocity regulator adaptive control
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
60
0x205E
Velocity
regulator
inflection
velocity 1
‰VN
1~1000
800
Immediately
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
61
0x205F
Velocity
regulator
inflection
velocity 2
‰VN
1~3000
1500
Immediately
Parameter description:
If Byte3 of 0x2065 is set to 0x10 or 0x11, inflection velocity 1 and 2 of the velocity
regulator take effect. For detailed information about velocity regulator adaptive control, please refer to the figure
below, "Diagram of velocity PI gain automatic switching". VN: Motor rated speed
User permission:
User/Engineer
Parameter permission:
Read and Write
Diagram of velocity PI gain automatic switching:
162
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...