background image

 

 

 

 

 

 

 

 

 

 
Installation Guide V1.1 
DUET AD 

 

 

 

 

Summary of Contents for DUET AD

Page 1: ...Installation Guide V1 1 DUET AD ...

Page 2: ...T AD 2 8 02 9 5 6 Accessories 9 6 Protective functions 10 6 1 Ballast circuit 10 6 2 Current limitation 10 7 Installation 11 8 Mechanical assembly 11 8 1 EMI compatibility 11 8 2 Ground wire 12 8 3 Motor power supply 13 8 4 Signal interface supply 15 8 5 Schematic circuit of the digital inputs 16 8 6 Schematic circuit of the digital outputs 17 8 7 Maximum cable length and power supply 18 9 Connect...

Page 3: ...h information is supplied solely for the purpose of assisting users of the DUET AD in its installation and configuration The text and graphics included in this manual are for the purpose of illustration and reference only The specifications on which they are based are subject to change without notice Motor power Company and the Motor power Company logo are trademarks of Motor power Company Srl Inf...

Page 4: ...t possible effect 3 General Description 3 1 DUET AD The DUET AD represents EC motors brushless DC motor with an integrated torque speed position control electronic and a 14 bit single turn absolute encoder The desired command can be set via analogue signal input 0 10 V The four operating modes clockwise rotation counter clockwise rotation Off rapid break point with freewheel and Stop rapid breakpo...

Page 5: ... components specified by Motor Power Company The Device may only be put into operation once the entire system has been installed in accordancewith EMC Please follow the instructions in chapter 7 2 3 3 Standards and guidelines EU guidelines the EU guidelines formulate the minimum requirements made on a product and must be observed by all manufacturers and dealers marketing the product in the member...

Page 6: ... damage to the equipment Disconnect the electrical power supply before any operation on the device NOTICE The drive must only be installed and adjusted by qualified persons in accordance with the relevant standards Qualified persons are those who based on their experience can recognize and avoid potential dangers are familiar with the accident prevention regulations for the equipment deployed can ...

Page 7: ...78 V Required external fuse 25 AT external Overtemperature protection 110 C at the power output stage Max peak current 2 sec 50 A Current consumption of 24 V logic supply 70 mA power of digital outputs 5 2 Mechanical data Device Temperature range 20 C 100 C housing temperature Recommended environmental temperature range 0 C 40 C Storage Temperature 20 C 50 C Relative humidity Max 90 not condensing...

Page 8: ... refer to this ambient temperature The protective system only refers to the device casing The shaft is to be sealed by the client The drive may only be used in an environment complying with IP54 if the shaft outlet has been installed such that it is protected from dust and water 5 3 Dimensions 5 4 DUET AD 1 5 03 ...

Page 9: ...e 48V Nominal power 630 W Rated speed 3000 rpm Rated torque 2 Nm Rated current 17 7 Arms Weight approx 3 1 Kg Rated output with 250x250x6mm heat sink flange 5 6 Accessories Planetary gear Available high efficiency planetary gears with very compact design Configuration direct coupling also available Available gear ratio from 3 1 216 1 Brake The device can be fitted with a power off brake option ...

Page 10: ...commends a resistor of 4 7Ω The ballast resistor must be defined depending on the braking power at least 50watts It is necessary to use a fuse of 6 3AT against overloading of the ballast resistor The ballast circuit switches on at 52V and off at 50V device voltage It does only work and protect the device and supply if the ballast resistor is connected like shown in chapter 8 1 8 2 According to sta...

Page 11: ...ice must be fastened to a flat surface using 4 screw connections The flange screws must be prevented from distortion by means of spring washers The motor shaft axial and radial loads are Radial load 350N applied on the shaft center Axial load 110N applied on the shaft center 8 1 EMI compatibility Electromagnetic radiated interferences occur in the DUET AD and the machine in which the drive is inst...

Page 12: ...nnection of all components in the system o Hidden shielded cable routing in metal ducts o Using additional suppression components ferrite or filter modules o Additional storage capacitors The electromagnetic compatibility of the machine must be tested and ensured before it is put into operation 8 2 Ground wire The motor housing must be connected to the machine earth via a separate earth wire Pleas...

Page 13: ... Power Company 2 By default Pin 4 is connected to the motor housing via the motor connector housing Therefore it is not suited as protective earth but only as functional earth NOTICE Not turning the connector of more than 180 Consequence Short circuit short circuit to frame or malfunction by unfixed wires at the solder point possible ...

Page 14: ...ase order in addition For DUET AD with 4 pin connector pre assembled connection cables are available in a range of lengths from stock On one end these cables have the appropriate 4 pin right angle connector already fitted The following cable lengths are available Cable length 5000mm MPC code 003108020546 ...

Page 15: ...le 005117000356 CONNETTORE VOL POT BSTA896FR0985202A000 4p M17 8 4 Signal interface supply Plug Round plug to DIN 45326 Binder Series 723 The 12pin motor connector is for logic supply of the motor Ref drawing EDADC Inserire disegno cavo segnale ref Drawing N13H13 ...

Page 16: ...connection cables of Motor Power Company The following cable lengths are available Cable length 5000mm MPC code 003108009843 Mating connector is available 005117002496 CN VOL SEG M16 12P FM 99 5630 75 12 8 5 Schematic circuit of the digital inputs Da rifare disegno ...

Page 17: ...ector pre assembled connection cables are available in a range of lengths from stock On one end these cables have the appropriate 12 pin right angle connector already fitted At the other end the cable is simply cut off NOTICE Not turning the connector of more than 45 45 Consequence Short circuit short circuit to frame or malfunction by unfixed wires at the solder point possible ...

Page 18: ...chematic Warning Before commissioning it is essential that the safety instructions in the relevant section are read and understood and then observed Non observance can result in danger to persons or damage to the equipment Disconnect the electrical power supply before any operation on the device CAUTION Incorrect connection of motor power electronics The motor is not equipped with reverse polarity...

Page 19: ...ng must be spaciously applied inside the control cabinet Failure to follow them can result in danger to persons or damage to the equipment 9 1 Schematic circuit for power supply controller CAUTION Peak current by switching on of a variety of series connected motors Consequence Destroying of the integrated electronics possible Using a soft start resistor or adeguate power supply The grey section of...

Page 20: ...DUET AD Installation Guide Pag 20 9 2 Connection motor power supply ...

Page 21: ...nstallation Guide Pag 21 9 3 Connection signal interface supply 9 4 Can Open connection Interface Ref drawing EDADC Note this connector is available only on DUET AD Can Open version Mating connector is available ...

Page 22: ...king Out of Service NOTICE The safety instructions must be read and observed prior to taking the unit out of service Disposal Take the drive out of service see above Dismantle the drive ready for disposal and break it up into its individual components Sort the individual parts according to material and forward for disposal Adherence to the requirements of legislation governing disposal and environ...

Page 23: ...allation Guide Pag 23 10 2 Service Support Should you have any questions or problems please contact Our local distributor Our Location Worldwide You can also visit our online support at http www motorpowergroup com ...

Reviews: