background image

http://www.rhinomc.com

 

Page 1

 

BLDC Motor Drive 50W [RMCS-3002]

 

 

RHINO MOTION CONTROLS

 

RMCS-3002 

Brushless DC motor Driver 50W 

(Max. 30VDC and 3A per phase) 

 
 
 

 

 

Installation Manual and Datasheet 

RMCS-3002

 

 
 

 

Summary of Contents for RMCS-3002

Page 1: ...http www rhinomc com Page 1 BLDC Motor Drive 50W RMCS 3002 RHINO MOTION CONTROLS RMCS 3002 Brushless DC motor Driver 50W Max 30VDC and 3A per phase Installation Manual and Datasheet RMCS 3002 ...

Page 2: ...tion 4 Electrical safety measures 4 Chapter 2 Drive Overview 5 Drive Acceptance 5 Key Features 5 Applications 6 Chapter 3 Drive Parameters and Connections 6 Drive Technical Characteristics 6 Connector Description 7 Mechanical Specifications 8 Power supply Selection 9 LED Status and Error Codes 9 Parameter Settings 9 Chapter 4 Trouble Shooting 10 Self Testing 10 User Level Trouble Shooting Guide 10...

Page 3: ...ON CONTROLS RMCS 3002 Brushless DC motor Driver 50W Max 30VDC and 3A per phase List of Tables Table 1 Electrical Characteristics 6 Table 2 Hall Sensor Terminal 7 Table 3 Motor Terminal Assignments 7 Table 4 Power Terminal Assignments 7 Table 5 Control Input Assignments 8 ...

Page 4: ...ndition else it may damage the driver To avoid personal injury and property loss only qualified and service trained personnel should operate the driver Do not insert any object into the driver which may cause damage to the driver If any fault occurs to the driver while operations please return it for maintenance repair Trying to repair the driver without any authorization or improper operation may...

Page 5: ...d under voltage protection and will survive accidental motor disconnects while powered up Driver Acceptance Upon receiving the driver please check the following aspects Make sure the driver model is consistent with that ordered Unpack the driver and make sure it is free from damage and no part is missing Make sure that all sets of screws in the driver are securely tightened Key Features Smooth and...

Page 6: ...pical applications include CNC routers laser cutters laser markers medical equipments X Y tables measurement equipments etc Chapter 3 Drive Parameters and Connections Drive Technical Characteristics Table 1 Electrical Characteristic Specification Min Max Units Comments Supply Voltage 10 30 Volt DC Between ve and GND Phase Current 0 5 3 Ampere As demanded by load ...

Page 7: ...erminal 1 GND Ground Terminal 2 5V Power ve 5V output Terminal 3 HW BLUE Hall W Terminal 4 HV GREEN Hall V Terminal 5 HU Yellow Hall U Table 3 Motor Terminal Assignments Terminal No Terminal Name Description Terminal 6 W Motor Phase Terminal 7 V Motor Phase Terminal 8 U Motor Phase Table 4 Power Terminal Assignments Terminal No Terminal Name Description Terminal 9 V ve Power supply 10VDCto30VDCMax...

Page 8: ...r phase Table 5 Control Input Assignments Terminal No Terminal Name Description Terminal 11 GND COM Terminal 12 RXD Connect to Receive pin Terminal 13 TXD Connect to Transmit pin Terminal 14 ENA Enable Motor Free ve Input Terminal 15 ADC ADC Terminal 16 DIR Direction Motor Change Directions ve Input Terminal 17 BRK Brake Motor Lock ve Input ...

Page 9: ...een LED glows For self testing connect the motor phase properly and make sure that LED status is correct Supply the 3 3v 5V to enable pin to enable the rotation of motor shaft Also change the current settings in potentiometer if necessary Current setting potentiometer is provided inside the drive You need to remove the top to change the current gain Speed can be altered using external potentiomete...

Page 10: ...u have gone through this entire installation manual and datasheet before deciding that your product is liable for replacement or repair under this 6 month warranty Customer shall prepay shipping charges for products returned to Rhino Motion Controls for warranty service and Rhino Motion Controls shall pay for return of products to customer Warranty Limitations Rhino Motion Controls makes no other ...

Reviews: