15-11
15.2 Processing solution Heater/Circulation Pump Section
15
5. Loosen the two screws and remove the drain cock
from the bracket.
6. Loosen the two screws and remove the pump
bracket.
7. Pull out the pump bracket, pinch the inlet and
outlet hoses with the two pinchcocks and drain the
solution in the hose from the drain cock.
8. Loosen the hose clamps and disconnect the inlet
and outlet hoses from the pump.
9. Remove the two screws and then the pump.
Installation
Installation is essentially in the reverse order of removal.
NOTE: Connect the hoses securely
Removal
1. Drain the PS1 to PS4 processing solutions.
2. Remove:
• Upper connector cover
• Heater cooling fan
3. Remove the two screws securing the upper
connector bracket.
4. Open the four harness clamps.
5. Loosen the two screws and move the lower
connector bracket to one side.
LII661
Screws (2)
Drain Cock
Screws (2) (Loosen)
Pump Bracket
LII662
Pinchcocks (2)
Drain Cock
Clamp
Outlet Hose
Inlet Hose
Screws (2)
Pump
(PU700)
Pump (PU701)
15.2.6
PS1 to PS4 Circulation Pump (PU702 to PU705) Replacement
LII657
Screws (2)
Upper Connector Bracket
Clamps (4)
Screw (Loosen)
Screw (Loosen)
Lower Connector Bracket