3-60
3.2 Messages and Actions
W-2696
Switching operation in feed
lane(S770/D776) abnormal.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
Abnormal operation of the feeding
path switching guide is detected.
(Causes of the error message)
1. Foreign matter such as jammed
paper in the feeding path switching
guide section
2. Incorrectly positioned solenoid
(Solenoid dog does not reach the
sensor.)
3. Poorly connected or broken
harness between the sorter tray
section solenoid (S770) and
PDB11 on the PDB23 circuit board
4. Poorly connected or broken
harness between the feeding path
switch position sensor (D776) and
JNE3 on the JNE23 circuit board
5. Faulty S770
6. Faulty D776
7. Faulty PDB23 circuit board
1. Remove foreign matter.
2. Adjust the position of the solenoid.
3. Connect the harness correctly, or
repair or replace it.
4. Connect the harness correctly, or
repair or replace it.
5. Replace S770.
6. Replace D776.
7. Replace the PDB23 circuit board.
I-2697
Opening not completed normally.
Check that replenisher cartridge is
properly installed.
Restart processing.
Cartridge opening is not completed at
the previous operation.
–
W-2698
Wrong machine or processing type.
Message for service engineer.
Consult your technical representative.
(Causes of the error message)
1. Machine or processing type is not
met.
1. Use correct machine or processing
type.
E-2699
Transversal sorter operation(M811/
D813) abnormal.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
Abnormal operation of the transversal
sorter is detected.
(Causes of the error message)
1. Poorly connected or broken cable
between the transversal sorter and
processor.
2. Poorly connected or broken
harness between the transversal
sorter drive motor (M811) and
PDB10 on the PDB23 circuit board
3. Poorly connected or broken
harness between the transversal
sorter stop sensor (D813) and
JNE4 on the JNE23 circuit board
4. Faulty M811
5. Faulty D813
6. Faulty PDB23 circuit board
7. Increased load in the belt drive
system
1. Connect the cable correctly, or
repair or replace it.
2. Connect the harness correctly, or
repair or replace it.
3. Connect the harness correctly, or
repair or replace it.
4. Replace M811.
5. Replace D813.
6. Replace the PDB23 circuit board.
7. Repair or replace the drive system.
W-2740
As processor section is in process,
the printer maintenance not started.
–
Wait until processing is completed.
W-2750
Control strip processing error
occurred.
Control strip processing has been
canceled.
–
Clear the error and then perform
control strip processing again.
E-2752
Power failure in PS4 tank leak
solution sensor circuit.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
Abnormal power supply to solution
concentration detecting circuit
(Causes of the error message)
1. Poorly connected or broken
harness between the PS4 solution
concentration sensor (FS706) and
CTL7 on the CTL23 circuit board
2. Faulty FS706
3. Faulty CTL23 circuit board
1. Connect the harness correctly, or
repair or replace it.
2. Replace the FS706circuit board.
3. Replace the CTL23 circuit board
No.
Message
Factor
Actions