3-49
3.2 Messages and Actions
3
NOTE 2: Press the densitometer reset switch.
Reset Switch (AD300)
W-2568
Ejecting of the print failed.
Insert the condition setup print into
the densitometer correctly, and
perform the measurement again.
Chart is not ejected from the
densitometer.
(Causes of the error message)
1. Jammed chart in densitometer
1. Press the [Reset] button to eject
the chart. If not ejected, pull out
the chart by hand and press the
[Reset] button. (NOTE 2)
W-2569
Check the outputted setup print and
then perform the density
measurement again.
Density measurement operation error
for condition setup printing
(Causes of the error message)
1. Densitometer error (Red LED
lights.)
2. Faulty densitometer
1. Reset the densitometer. (NOTE 2)
2. Replace the densitometer.
I-2573
Laser temperature adjustment not
completed in exposure section.
Please Wait.
–
–
E-2580
R laser (R LD)CB temperature error
occurred.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
R laser CB temperature is outside the
specified range.
(Causes of the error message)
1. Faulty CB temperature control
section on the LDR23 circuit board
1. Replace the laser optical unit.
W-2590
Door opened.
(Causes of the error message)
1. Door is opened during
maintenance mode.
1. Close the door.
W-2591
Cannot be performed due to the lack
of conditions
(Causes of the error message)
1. Operation is directed when the
conditions are not met.
1. Check the operation conditions.
W-2601
Paper jam in processor (8).
Check it. ### sheets remain.
Press [Help] button to see error help
(or manual). Remove paper while
referring to it.
Paper is not fed out within the
specified time.
(Causes of the error message)
1. Paper jamming
2. Faulty feeding path switching
paper sensor (D770/D771/D772)
3. Incorrectly set processing rack,
crossover rack, dryer rack, etc.
4. Faulty dryer rack or abnormal
drying temperature control
5. Faulty dryer exit section
1. Remove paper.
2. Replace D770/D771/D772.
3. Set the rack properly.
4. Replace the dryer rack.
5. Replace the faulty part(s) in the
dryer exit unit.
W-2602
Paper remains in processor.
Press [Help] button to see error help
(or manual). Remove paper while
referring to it.
Power is turned OFF while paper
remains in processor.
Check the processor and dryer
sections and dryer exit unit. If paper
remains, remove it.
No.
Message
Factor
Actions