3-108
3.2 Messages and Actions
NOTE 1: The refreshing backup can be restored
(See Section 3.4)
.
E-4689
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-serial Transmission Driver 3
parity and framing error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CPZ23 circuit board (CPU)
1. Click [OK].
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4690
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-serial Transmission Driver 3
overrun error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CPZ23 circuit board (CPU)
1. Click [OK].
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4691
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-serial Transmission Driver 3
overrun and parity error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CPZ23 circuit board (CPU)
1. Click [OK].
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4692
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-serial Transmission Driver 3
overrun and framing error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CPZ23 circuit board (CPU)
1. Click [OK].
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4693
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-serial Transmission Driver 3
overrun, framing and parity error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CPZ23 circuit board (CPU)
1. Click [OK].
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
No.
Message
Factor
Actions