5-77
5.5 Carrier Adjustment/Maintenance (04)
5
4. Click the [OK] button.
• The data is saved.
5. Click the [Close] button.
• Operation returns to the menu screen.
The image frame size displayed after pre-scanning
can be set up in this menu.
The initial values are set to optimum condition.
Changing of this value may result in a mask frame,
etc. appearing on the monitor screen.
[Selection]
[Setup and Maintenance]
→
[04 Carrier Adjustment/
Maintenance]
→
[0426 MFC10AY Monitor Frame
Ratio Setup]”
1. Select the carrier ID to be set up.
2. Change the monitor frame ratio by clicking the [
▼
]
and [
▲
] buttons.
NOTE: Enter 95% for 135F and smaller masks, and
98% for 120 and 135FP masks normally.
3. Click the [Storage] button.
4. Click the [OK] button.
• The data is saved.
5. Click the [Close] button.
• Operation returns to the menu screen.
5.5.8
MFC10AY Monitor Frame Ratio Setup (0426)