3-106
3.2 Messages and Actions
NOTE 1: The refreshing backup can be restored
(See Section 3.4)
.
E-4672
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery memory
pool obtaining error 0
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4673
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery memory
pool release error 0
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4674
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery memory
pool obtaining error 1
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4675
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery memory
pool release error 1
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4676
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery
semaphore obtaining error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4677
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery
semaphore return error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4678
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery
semaphore reference error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4679
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-system initialization error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4680
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-task creation error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
No.
Message
Factor
Actions