16-20
16.2 Processing Solution Replenishment System
6. Loosen the five hose clamps and disconnect the
five hoses from the tank.
7. Remove the tank.
Installation
Installation is essentially in the reverse order of removal.
NOTE: • Connect the hoses securely
• Use a new toothed washer for tightening the
grounding wire to the frame.
• After installation, perform Installation Menu "91
PSR AIR EXT" from the operation panel on the
LP5700.
Removal
1. Remove the right cover
2. Drain remaining solutions from the tanks.
3. Remove the four screws and then the fan duct.
4. Remove the two screws and then the upper
connector bracket.
5. Loosen the four hose clamps and disconnect the
three inlet hoses and stirring hose.
LII731
Clamps (5)
Hoses (5)
Tank
16.2.11
P1R/P2RA/P2RB Tank Replacement
LII653
Screws (4)
Fan Duct
LII1170
Clamps (4)
Inlet Hose
Stirring Hose