8-15
8.2 Scanner Section
8
10. Remove the screw and then the clamp.
11. Disconnect the JPC2 connector.
12. Remove the three screws and then the CCD unit.
Reinstallation
Reinstallation is essentially in the reverse order of
removal.
When the CCD unit has been replaced, perform the
following adjustments after installation.
1) In Menu 0350 “Scanner Parameter Check/
Update” insert a parameter FD attached to the
new CCD unit and click the [FD reading]
button to download the parameter from the FD
into the HD of the main control unit and the
EEPROM on the CPZ23 circuit board
2) In Menu 0351 “CCD Adjustment” perform “AD
timing adjustment”, “OFD voltage adjustment”
and “Gray pixel detecting”
Z
2
136
JPC2 Connector
Screw/Clamp
Z
2
137
Screws (3)
CCD Unit