7-23
7.1 Auto Film Carrier NC100AY (Pressure Cover Section)
7
3. Turn the hex. socket head setscrew with the
1.5mm hex wrench so that the clearance between
the 135F upper mask and the lower mask is
specified value.
Specified Clearance: 0.7 to 0.9 mm
4. Apply thread locking agent to the setscrew and
tighten the locknut.
Thread Locking Agent: LOCTITE 425 or equivalent
1. Remove the pressure upper cover
2. Connect the Auto Film Carrier NC100AY to the
plug-in connector of the scanner using a carrier
extension cable.
3. Open the Menu 0421 “NC100AY Input Check”
screen.
4. Loosen the locknut.
5. Close the pressure cover and turn the pin to find a
point that “D128” just turns “Open” and “Close”.
6. Screw in the pin 1.25 turns.
7. Apply thread locking agent to the threads of the
pin and tighten the locknut securely.
Thread Locking Agent: LOCTITE 425 or equivalent
8. Disconnect the carrier extension cable and
reinstall the pressure upper cover.
Z
2
304
Hex Socket Head Setscrew
Locknut
135F Lower Mask
0.7 to 0.9mm
135F
Upper Mask
7.1.16
Pressure Cover Open/Close Detecting Pin Position Adjustment
Z
2
268
Pin
Locknut
Lock Screw