3-102
3.2 Messages and Actions
NOTE 1: The refreshing backup can be restored
(See Section 3.4)
.
E-4637
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C higher-order address
sending failure
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4638
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C lower-order address
sending error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4639
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C lower-order address
sending failure
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4640
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C data sending error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4641
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C data sending failure
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4642
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C sending off error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4643
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C bus free detecting error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4644
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C start bit sending error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
No.
Message
Factor
Actions