13-32
13.2 Distribution Unit
Removal
1. Remove the distribution unit
2. Disconnect the motor connector and open the
clamp.
3. Remove the motor connector from the bracket.
4. Remove the tension adjustment spring.
5. Remove the two screws and then the motor.
6. Remove the two screws and then the bracket from
the motor.
Installation
Installation is essentially in the reverse order of removal.
NOTE: • Note the motor connector position when installing
the bracket.
• Install the tension adjustment spring then tighten
the two screws.
13.2.10
Distribution Slide Motor (M661) Replacement
LII540
Connector
Clamp
Spring
Screws (2)
Motor
LII541
Screws (2)
Bracket
Motor (M661)