8-21
8.2 Scanner Section
8
3. Open the clamp and disconnect the motor
connector.
4. Remove the three screws and then the motor.
Installation
Installation is essentially in the reverse order of
removal.
After installation perform the following adjustments.
1) Menu 0346 “Optical Magnification Calibration”
2) Menu 0347 “Focus Calibration”
3) Menu 0321 “Focus Position Adjustment”
Removal
1. Remove the scanner section brackets
2. Remove the screw and then the sensor bracket.
3. Disconnect the connector from the sensor.
Z
2
123
Motor
Connector
Conjugate Length
Variable Motor (M201)
Screws (3)
Clamp
8.2.15
Conjugate Length Variable Section Home Position Sensor
(D201) Replacement
Z
2
131
Connector
Sensor Bracket
Screw