3-30
3.2 Messages and Actions
W-2416
Initializing of nip in exposure section
(M651/D651) failed.
Open and close magazine door. If
problems persist, consult your
technical representative.
Exposure soft nip home position is
not detected (Sensor did not function
even if the soft nip motor is driven
specified pulses).
(Causes of the error message)
1. Poorly connected or broken
harness between the soft nip
home position sensor (for M651)
(D651) and JND6 on the JND23
circuit board
2. Poorly connected or broken
harness between the soft nip
motor (M651) and PDA11 on the
PDA23 circuit board
3. Faulty D651
4. Faulty M651
5. Faulty exposure nip mechanism
6. Faulty PDA23 circuit board
7. Faulty CTL23 circuit board
1. Connect the harness correctly, or
repair or replace it.
2. Connect the harness correctly, or
repair or replace it.
3. Replace D651.
4. Replace M651.
5. Replace the sub scanning unit.
6. Replace the PDA23 circuit board.
7. Replace the CTL23 circuit board.
W-2417
Initializing of sub-scanning receiving
section nip(M655/D655/M656/D656)
failed.
Open and close magazine door. If
problems persist, consult your
technical representative.
Distribution entrance section nip
home position is not detected.
(Causes of the error message)
1. Poorly connected or broken
harness between the nip release
home position sensor 2/3 (D655/
D656) and JND7 on the JND23
circuit board
2. Poorly connected or broken
harness between the nip release
motor 1/2 (M655/M656) and
PDA12 on the PDA23 circuit board
3. Faulty D655/D656
4. Faulty M655/M656
5. Faulty distribution entrance section
nip mechanism
6. Faulty PDA23 circuit board
7. Faulty CTL23 circuit board
1. Connect the harness correctly, or
repair or replace it.
2. Connect the harness correctly, or
repair or replace it.
3. Replace D655/D656.
4. Replace M655/M656.
5. Replace the distribution entrance
unit.
6. Replace the PDA23 circuit board.
7. Replace the CTL23 circuit board.
W-2418
Initializing of distribution section
nip(M662/D662/M663/D663) failed.
Open and close magazine door. If
problems persist, consult your
technical representative.
Distribution section nip home position
is not detected.
(Causes of the error message)
1. Poorly connected or broken
harness between the nip release
home position Sensor 4 (front/
rear) (D662/D663) and JND8 on
the JND23 circuit board
2. Poorly connected or broken
harness between the Nip Release
Motor 4 (front/rear) (M662/M663)
and PDA14 on the PDA23 circuit
board
3. Faulty D662/D663
4. Faulty M662/M663
5. Faulty distribution section nip
mechanism
6. Faulty PDA23 circuit board
7. Faulty CTL23 circuit board
1. Connect the harness correctly, or
repair or replace it.
2. Connect the harness correctly, or
repair or replace it.
3. Replace D662/D663.
4. Replace M662/M663.
5. Replace the distribution unit.
6. Replace the PDA23 circuit board.
7. Replace the CTL23 circuit board.
No.
Message
Factor