3-115
3.2 Messages and Actions
3
E-4738
An abnormality occurred during
initializing of the piezoelectric
actuator.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-piezoelectric actuator
warming-up position 6 error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
E-4739
An abnormality occurred during
initializing of the piezoelectric
actuator.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-piezoelectric actuator
warming-up position 7 error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
E-4740
An abnormality occurred during
initializing of the piezoelectric
actuator.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-piezoelectric actuator
warming-up position 8 error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
E-4741
The LED setting failed.
Restart the system. If problems
persist, consult your technical
representative.
Data returned from CLE circuit board
differs from GIA circuit board setup
data.
(Causes of the error message)
1. Faulty harness between GIA23
and CLE23 circuit boards
1. Reconnect or replace the harness.
E-4742
The setting for the piezoelectric
actuator failed.
Restart the system. If problems
persist, consult your technical
representative.
Data returned from CPZ circuit board
differs from GIA circuit board setup
data.
(Causes of the error message)
1. Faulty harness between GIA23
and CPZ23 circuit boards
1. Reconnect or replace the harness.
E-4743
The settings for LED and
piezoelectric actuator failed.
Restart the system. If problems
persist, consult your technical
representative.
Data returned from CLE circuit board
differs from GIA circuit board setup
data. Data returned from CPZ circuit
board differs from GIA circuit board
setup data.
(Causes of the error message)
1. Faulty harness between GIA23
and CLE23 circuit boards
2. Faulty harness between GIA23
and CPZ23 circuit boards
1. Reconnect or replace the harness.
2. Reconnect or replace the harness.
W-4744
Scanning was cancelled.
Canceling executed
(Causes of the error message)
1. [Cancel] button is clicked during
scanning
2. Faulty keyboard
1. Scan again if scanning is not
completed.
2. Replace the keyboard.
No.
Message
Factor
Actions