3-105
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
E-4662
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-temperature control task
receiving error
(Causes of the error message)
1. System software overload
(faulty software)
2. Faulty CLE23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4663
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-maintenance task receiving
error
(Causes of the error message)
1. System software overload
(faulty software)
2. Faulty CLE23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4664
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-illegal message receiving
(Causes of the error message)
1. System software overload
(faulty software)
2. Faulty CLE23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4665
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-EEPROM writing abnormal
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CLE23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4667
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery module
initialization error 1
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4668
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ- message delivery module
initialization error 2
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4669
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery message
sending error
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4670
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-message delivery message
sending error 1
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4671
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ- message delivery message
sending error 2
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
No.
Message
Factor
Actions