3-47
3.2 Messages and Actions
3
NOTE 2: Press the densitometer reset switch.
Reset Switch (AD300)
W-2556
Initializing is in progress, so density
measurement cannot be started.
After initialization, retry
measurement.
Density measurement cannot be
started because the densitometer
initialization is in progress.
(Causes of the error message)
1. Initializing densitometer
1. Wait until densitometer
initialization is completed.
W-2557
Density measurement cannot be
started.
Press the [Reset] button of the
densitometer, and then retry it.
Density measurement cannot be
started because error has been
occurred in the densitometer.
(Causes of the error message)
1. Densitometer error (Red LED
lights.)
1. Press the [Reset] button to
initialize the densitometer.
(NOTE 2)
W-2558
Check the connection of the
densitometer and the power cable,
retry it.
If problems persist, consult your
technical representative.
Signal for starting density
measurement is not received from
the densitometer within the specified
time.
(Causes of the error message)
1. Disconnected cable before
measurement
2. Turned OFF power supply for
densitometer before measurement
1. Connect the cable properly and
perform density measurement
again.
2. Make sure the power switch on the
densitometer is turned ON.
W-2559
Canceling of density measurement
failed.
Check if the paper remains.
Density measurement interruption
failed.
(Causes of the error message)
1. Jammed chart in the densitometer. 1. Press the [Reset] button to eject
the chart. If not ejected, pull out
the chart by hand and press the
[Reset] button. (NOTE 2)
W-2560
Canceling of density measurement
failed.
Consult your technical representative.
Communication busy state occurs
when interrupting density
measurement.
(Causes of the error message)
1. Collision occurred while
communicating with the
densitometer.
1. Press the [Reset] button to
initialize the densitometer.
(NOTE 2)
W-2561
Detecting of leading end of the print
failed.
Insert the upkeep print into the
densitometer correctly, and perform
the measurement again.
The leading end of the print upkeep
chart cannot be detected during
density measurement.
(Causes of the error message)
1. Chart is not inserted.
2. Insufficiently inserted chart.
1. Set the chart and perform density
measurement again.
2. Set the chart and perform density
measurement again.
No.
Message
Factor
Actions