3-113
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
E-4724
An error occurred during accessing of
the CPZ circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-EEPROM R/W error
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
W-4725
The adjustment data for the CPZ
circuit board external memory is
corrupted.
Restart the system. If problems
persist, consult your technical
representative.
Use of ROM data at starting
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4726
The control for the piezoelectric
actuator is abnormal.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-X axis control error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
E-4727
The control for the piezoelectric
actuator is abnormal.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-Y axis control error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
E-4729
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
When control requested to CPZ
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board
3. Faulty GIA23 circuit board
4. Faulty GMB23 circuit board
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
3. Replace the circuit board.
4. Replace the circuit board.
E-4730
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
When control requested to CPZ
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board
3. Faulty GIA23 circuit board
4. Faulty GMB23 circuit board
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
3. Replace the circuit board.
4. Replace the circuit board.
E-4731
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
When control requested to CPZ
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board
3. Faulty GIA23 circuit board
4. Faulty GMB23 circuit board
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
3. Replace the circuit board.
4. Replace the circuit board.
No.
Message
Factor
Actions