3-114
3.2 Messages and Actions
NOTE 1: The refreshing backup can be restored
(See Section 3.4)
.
E-4732
An error occurred during accessing of
the CPZ circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-EEPROM writing abnormal
(Causes of the error message)
1. Faulty system software
2. Faulty CPZ23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4733
An abnormality occurred during
initializing of the piezoelectric
actuator.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-piezoelectric actuator
warming-up position 1 error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
E-4734
An abnormality occurred during
initializing of the piezoelectric
actuator.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-piezoelectric actuator
warming-up position 2 error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
E-4735
An abnormality occurred during
initializing of the piezoelectric
actuator.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-piezoelectric actuator
warming-up position 3 error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
E-4736
An abnormality occurred during
initializing of the piezoelectric
actuator.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-piezoelectric actuator
warming-up position 4 error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
E-4737
An abnormality occurred during
initializing of the piezoelectric
actuator.
It is possible to continue printing, but
the resolution may be deteriorated
when you print with larger sizes than
4R.
Consult your technical
representative.
SKCPZ-piezoelectric actuator
warming-up position 5 error
(Causes of the error message)
1. Outside noise, such as cell phone
transmissions, etc.
2. Faulty displacement sensor
harnesses or piezoelectric
actuator harness
3. Faulty CPZ23 circuit board
4. Faulty displacement sensors, or
piezoelectric actuator
1. Keep the noise source far away.
2. Reconnect or replace the harness.
3. Replace the circuit board.
4. Replace the CCD unit.
No.
Message
Factor
Actions