3-14
3.2 Messages and Actions
E-1750
More frames than the specified
frames are detected.
Change the number of frames, or use
the piece film with the same number
of frames.
This message appears when the
system recognizes the strip film but
cannot find the frame with the starting
frame No. in the negative sheet index
print.
Change number of frames or use
piece film with specified number of
frames.
W-1751
#####
Couldn’t start scan. Eject film.
#####
The real-time display is unavailable.
(Causes of the error message)
1. A template used for mounted print
or frame/character is being
installed.
2. The “Output destination selection”
screen is being displayed for
exporting image file.
3. The “Original selection” screen is
being displayed.
4. The template selection screen for
mounted print or frame/character
is being displayed.
5. Exporting image files is in
progress.
6. The manual film carrier is installed
during the single scan digitizing.
7. The carrier or mask type does not
fit the composite type.
8. The “Image preview” screen used
for mounted print or frame/
character is being displayed.
9. The batch retrieval of exposure
conditions is in progress.
10. Negative sheet index screen is
being displayed or print is being
processed.
11. The Red-eye/Soft/Cross plug-in
is starting.
1. Wait until the template setting
finishes.
2. Select the output destination using
the “Output destination selection”
screen.
3. Close the “Original selection”
screen.
4. Select the template using the
template selection screen, and
then wait until it is set.
5. Wait until the file is output.
6. Set the auto film carrier.
7. Install the carrier or mask
corresponding to the composite
type.
8. Close the “Image preview” screen.
9. Close the “Exposure condition
retrieve setup” screen.
10. Wait until the negative sheet
index screen is closed or
processing is completed.
11. Quit the Red eye/Soft/Cross plug-
in screen.
W-1752
#####
Adjusting of the image position failed.
Reading end frame cannot be found.
(Causes of the error message)
1. Carrier/mask and composite type
do not match.
2. Batch retrieval of exposure
conditions in progress.
Install the correct carrier and mask.
1. Check the carrier and mask.
2. Wait until retrieval of exposure
conditions is completed.
No.
Message
Factor